Key Operation Instruction
1) In normal working status, screen display real time temperature.
2) Press Set key once. Screen will display start temperature.
3) Press Down key once. Screen display stop temperature
4) Press SET key. Led display P0, press UP or Down to switch code P0 P1 P2 P3.
P0 - Starting temperature
P1 - Stop temperature
P2 - Temperature correction
P3 - Delayed start
Product Working Principle: When the starting temperature is lower than the stopping temperature, the product will start to heat up, and when the starting temperature is greater than the stopping temperature, the product will start to cool.
Specification:
1.Power supply: AC 110-200V
2.Measure range: -50 ~ 110 C
3.Temperature resolution: 0.1
4.Measurement Accuracy: ±0.1
5.Refresh Rate: 0.5s
Sensor: NTC 10K waterproof sensor
6.Output: MAX 10A socket direct output
7.Number of Bottons: 3
8.Function: Set start temperature,stop temperature,Temperature correction and delay start
9.Size: 120mmx60mmx30mm
10.Power consumption: Static current ≤ 35MA,attract current ≤ 65MA
11.Output socket support EU plug :Yes